File: //etc/rc4.d/K25boottimemirroring_phase2
#!/bin/sh
# This is for RHEL systems
# chkconfig: 1235 25 25
# description: Scout script to boot time stack the mirror setup devices
# description: chkconfig 1234 25 25 for phase2
# This is for SLES systems
### BEGIN INIT INFO
# Provides: Scout_Boottimemirroring_Phase2
# Required-Start:
# Required-Stop:
# Default-Start: 1 2 3 5
# Default-Stop:
# Description: Scout script for setting up boot time mirror configuration-phase2
### END INIT INFO
# This script can be introduced into runlevel directories by just executing this command:
# "chkconfig --add boottimemirroring[_phase?]"
# RHEL chkconfig is a binary executable itself and also behaves well, i.e. the start/stop link numbers remain 92
# SLES chkconfig is a perl wrapper over insserv which is not at all under our control when it comes to link numbers
# TODO - So for SLES we have to use dependency mechanism
# For now, after running chkconfig, rename links to S92 and K92 (TODO)
# Adding bin dirs to PATH for 'sleep' command
PATH=/bin:/sbin:/usr/sbin:/usr/bin:$PATH
export PATH
get_runlevel()
{
# Check for systemd
which systemctl > /dev/null 2>&1
if [ $? -eq 0 ]
then
# The 'runlevel' command in systemd works different than
# sysvinit runlevels. On systemd, the a specific runlevel
# is only returned when it is reached, while sysvinit would
# return it as soon as the switch was requested. IOW, runlevel
# is changed at start in sysv init and at the end by systemd
# so we cant rely on runlevel command for systemd
#
# We check if shutdown.target (common for reboot and poweroff)
# is currently active to set appropriate runlevel. Current logic
# does not distinguish between poweroff and reboot and always
# marks runlevel=0 == poweroff. Similarly, it always returns
# runlevel=3 == multiuser+nw even for graphical env or single
# user mode. This needs to be changed if finer distinction is
# required.
#
systemctl list-units --type=target | grep start | grep -q "shutdown\.target" && RUNLEVEL=0 || RUNLEVEL=3
else
# RUNLEVEL variable is set only when this control script is invoked by init
# Other times, we have to fetch the runlevel ourselves
RUNLEVEL=${RUNLEVEL:-`/sbin/runlevel | cut -d' ' -f2`}
fi
}
#SUSE11 DRIVER LD OPTION
if [ -f /etc/SuSE-release ] && grep -q 'VERSION = 11' /etc/SuSE-release ; then
OSN=SLES11
fi
CreateFiltDrvNode()
{
if lsmod | grep involflt > /dev/null 2>&1 && [ ! -c /dev/involflt ]; then
local FILTDRVNODE_MAJ_NUM=`cat /proc/devices | grep involflt | cut -d" " -f1`
mknod /dev/involflt c $FILTDRVNODE_MAJ_NUM 0
fi
}
case "$1" in
start)
echo "Starting boottimemirroring service"
get_runlevel
date 2>&1 >> /.boottimemirroring.log
/etc/vxagent/bin/boottimemirroring.sh 2>&1 > /.boottimemirroring.log.tmp
cat /.boottimemirroring.log.tmp >> /.boottimemirroring.log
RETVAL=$?
# Touch /var/lock/subsys/boottimemirroring only if the OS is non-debian
if [ ! -e /etc/debian_version ] ; then
[ ! -f /var/lock/subsys/boottimemirroring ] && touch /var/lock/subsys/boottimemirroring
fi
;;
stop)
echo "Stopping boottimemirroring service"
RETVAL=0
;;
restart)
echo "Restarting boottimemirroring service"
RETVAL=$?
;;
status)
echo "Checking status for boottimemirroring service"
RETVAL=0
;;
*)
echo "Usage: $0 {start|stop|restart|status}"
exit 1
;;
esac